JB/550/155/002: Difference between revisions

Transcribe Bentham: A Collaborative Initiative

From Transcribe Bentham: Transcription Desk

Find a new page to transcribe in our list of Untranscribed Manuscripts

JB/550/155/002: Difference between revisions

Klaud123 (talk | contribs)
No edit summary
Klaud123 (talk | contribs)
No edit summary
Line 5: Line 5:
<note>Letter III.</note>  
<note>Letter III.</note>  


<head><note>Extent for a single Builing.</note></head>
<head>Extent for a single Building.</head>
<p>
<p>
it is supposed that 18 Foot might serve for the <hi rend="underline">tour</hi> <hi rend="underline">stories</hi> of cells, to be inspected,<lb/> as above, by <hi rend="underline">one story</hi> of the <hi rend="underline">Lodge</hi>: This would hold 96 persons:(36 feet for four<lb/> stories of cells, and tour of the Lodge: this would hold 192 persons:) 34<lb/> for six stories of cells, and three of the Lodge: this would hold 288 persons.)<lb/> And 54 feet, it is concerned, would not be an immodirate elivation.<lb/></p>  
it is supposed that 18 Foot might serve for the <hi rend="underline">two</hi> <hi rend="underline">stories</hi> of <hi rend="underline">cells</hi>, to be inspected,<lb/> as above, by <hi rend="underline">one story</hi> of the <hi rend="underline">Lodge</hi>: This would hold 96 persons:(36 feet for four<lb/> stories of cells, and two of the Lodge: this would hold 192 persons:) 54 <unclear>feet</unclear><lb/> for six stories of the cells, and three of the Lodge: this would hold 288 persons.)<lb/> And 54 feet, it is concerned, would not be an immoderate elevation.<lb/></p>  


  <p>The drawings which, I believe will accompany this, suppose four<lb/> for the number of stories of the Cells.</p>
  <p>The drawings which, I believe <del>will</del> will accompany this, suppose four<lb/> for the number of stories of the Cells.</p>
<p>
<p>
You will see, under the head of Hospitals, the reasons why <add>I conceive</add> <del>concieve</del><lb/> that even a leg height than 9 feet, deducting the thickng of a floor<lb/> supported by arches, might be suficiant for the Cells.</p>  
You will see, under the head of Hospitals, the reasons why <add>I conceive</add> <del>concieve</del><lb/> that even a less height than 9 feet, deducting the thickness of a floor<lb/> supported by arches, might be sufficient for the Cells.</p>  


<p>The <hi rend="underline">hapage</hi> might have, for its <hi rend="underline">height</hi>, either the height of<lb/> one story, or of two stories of Cells: according as the number of those<lb/> Cells wasted on four. The part own the pafage might, in either case, be<lb/> added to the Lodge,<del><gap/></del> to which it would thereby give a communication,<lb/> of each end, with the would without doors i and insure a Keeper against<lb/> the dangers of finding himself a passion <add>among</add><del><gap/></del> his prisoners.</p>     
<p>The <hi rend="underline">passage</hi> might have, for its <hi rend="underline">height</hi>, either the height of<lb/> one story, or of two stories of the Cells: according as the number of those<lb/> Cells was two on four. The part over the passge might, in either case, be<lb/> added to the Lodge,<del><gap/></del> to which it would thereby give a communication,<lb/> at each end, with the would without doors; and insure a Keeper against<lb/> the danger of finding himself a prisoner <add>among</add><del>to</del> his prisoners.</p>     
<p>
<p>
Should it be thought that in this way, the Lodge would not <add>have</add><lb/> light <del><add><gap/></add></del>enough, for the convenience of a man of <add>a</add> station competent to the<lb/> office, the deficiency might be supplied, <add>by</add> a void space, left in that part,<lb/> all the way up. You may call it if you please the <hi rend="underline">Central</hi> <hi rend="underline">Area</hi>. Into this space windows may open, when they are wanted, from the apartments<lb/> of the Lodge. It may be either left open at the loft or covered with a<lb/> skylight. But this expedsent, tho'it might add, in some respects, to <add>the</add></p>
Should it be thought that in this way, the Lodge would not <add>have</add><lb/> light <del><add><gap/></add></del>enough, for the convenience of a man of <add>a</add> station competent to the<lb/> office, the deficiency might be supplied, <add>by</add> a void space, left in that part,<lb/> all the way up. You may call it if you please the <hi rend="underline">Central</hi> <hi rend="underline">Area</hi>. Into this space windows may open, when they are wanted, from the apartments<lb/> of the Lodge. It may be either left open at the top or covered with a<lb/> skylight. But this expedient, tho'it might add, in some respects, to <add>the</add></p>
<!-- DO NOT EDIT BELOW THIS LINE -->
<!-- DO NOT EDIT BELOW THIS LINE -->
{{Metadata:{{PAGENAME}}}}
{{Metadata:{{PAGENAME}}}}

Revision as of 15:55, 18 May 2016

Click Here To Edit 4 Letter III.

Extent for a single Building.

it is supposed that 18 Foot might serve for the two stories of cells, to be inspected,
as above, by one story of the Lodge: This would hold 96 persons:(36 feet for four
stories of cells, and two of the Lodge: this would hold 192 persons:) 54 feet
for six stories of the cells, and three of the Lodge: this would hold 288 persons.)
And 54 feet, it is concerned, would not be an immoderate elevation.

The drawings which, I believe will will accompany this, suppose four
for the number of stories of the Cells.

You will see, under the head of Hospitals, the reasons why I conceive concieve
that even a less height than 9 feet, deducting the thickness of a floor
supported by arches, might be sufficient for the Cells.

The passage might have, for its height, either the height of
one story, or of two stories of the Cells: according as the number of those
Cells was two on four. The part over the passge might, in either case, be
added to the Lodge, to which it would thereby give a communication,
at each end, with the would without doors; and insure a Keeper against
the danger of finding himself a prisoner amongto his prisoners.

Should it be thought that in this way, the Lodge would not have
light enough, for the convenience of a man of a station competent to the
office, the deficiency might be supplied, by a void space, left in that part,
all the way up. You may call it if you please the Central Area. Into this space windows may open, when they are wanted, from the apartments
of the Lodge. It may be either left open at the top or covered with a
skylight. But this expedient, tho'it might add, in some respects, to the


Identifier: | JB/550/155/002"JB/" can not be assigned to a declared number type with value 550.

Date_1

Marginal Summary Numbering

Box

550

Main Headings

Folio number

155

Info in main headings field

Image

002

Titles

Category

Number of Pages

Recto/Verso

Page Numbering

Penner

Watermarks

Marginals

Paper Producer

Corrections

Paper Produced in Year

Notes public

ID Number

Box Contents

UCL Home » Transcribe Bentham » Transcription Desk
  • Create account
  • Log in